PPA500功率分析儀
Leading wideband accuracy Basic 0.01% with class leading high frequency performance
Wide frequency range DC, 10mHz to 2MHz - PPA5500 / DC, 10mHz to 1MHz - PPA1500 / DC, 10mHz to 500kHz - PPA500Fast sample rate and No-Gap 2.2M samples/s - PPA5500 / 1M samples/s - PPA1500/500, High accuracy in noisy applicationsLeading phase accuracy 0.005 Degrees plus 0.01 degrees per kHzBuilt in high precision current shunt 10Arms, 30Arms or 50Arms with up to 1000Apk direct plus a wide range of external sensorsVersatile interfaces RS232, USB, LAN, GPIB (PPA5500) plus direct torque and speed (PPA5500)Range of PC software options Remote control, monitoring and recording of real time data, tables and graphs PPA500Series
In Harmonic Analyzer Mode, the PPA1500/PPA500 provides up to 50 Harmonics with real time, table or bar graph presentation(*No Graph presentation in PPA500). Measurements are in absolute magnitude and percentage of fundamental with harmonic phase also available. The PPA5500 extends the harmonic range to 417 for aerospace applications and also includes an FFT spectrum mode for interharmonic analysis (Available instead of IEC61000
1MHz/ PPA500 DC, 10mHz~ 500kHz |
Norma
1Vpk~2500Vpk(1000Vrms) in 8 ranges
x10 100mVpk~300Vpk in 8 ranges
Normal0.05% Rdg+0.1% Rng+(0.005%×kHz)+5mVx100.05% Rdg+0.1% Rng+(0.01%×kHz)+1mV
1mVpk~3Vpk in 8 ranges【BNC connector 3Vpk max input】
0.05%Rdg+0.1%Rng+(0.005%×kHz)+5µV
20Arms (PPA1500)Shunt 4mm Safety Connectors RangesNormal100mApk~300Apk(20Arms) in 8 ranges
x1010mApk~30Apk in 8 ranges
AccuracyNormal0.05% Rdg+0.1% Rng+(0.005%×kHz)+500µA x100.05% Rdg+0.1% Rng+(0.01%×kHz)+100µA
30Arms (PPA1500-HC)Shunt 4mmSafety Connectors
RangesNormal300mApk~1000Apk(30Arms) in 8 rangesx1030mApk~100Apk in 8 ranges
AccuracyNormal0.05% Rdg+0.1% Rng+(0.005%×kHz)+1mA
x100.05% Rdg+0.1% Rng+(0.01%×kHz)+300µA
BNC connector (Max input 3Vpk)
Ranges1mVpk~3Vpk in 8 ranges
Accuracy0.05% Rdg+0.1% Rng+(0.005%×kHz)+5µV
Norma0.01deg+(0.01deg×kHz) 0.01deg+(0.02deg×kHz)
Normal[0.1%+0.1%/pf+(0.01%×kHz)/pf] Rdg+0.1%VA Rngx10[0.1%+0.1%/pf+(0.02%×kHz)/pf] Rdg+0.1%VA Rng
40-400HzAs above with range error reduced from +0.1%V,A,VA Rdg to +0.05%V,A,VA Rng
Sample Rate1Ms/s on all channels, No-Gap
Application Modes
Ballast, Inrush, Standby Power
Connection Clips4mm terminated aligator clips - 1x red, 1x yellow and 2x black per phase (1x red and 1x black per phase with PPA5500-HC version)CD-ROMCommView2 (RS232/USB/LAN), Command line, Script based communication softwareDocumentsUser manual, Communications manual, Calibration certificate, Quick start guide
Dimensions |
92H×215W×312D mm excluding feet
¥1.0元
¥1.0元
¥1.0元
¥1.0元